Your local building inspector can let you know what the most current guidelines are for electrical safety around pools and spas.
Pool electrical code.
In other words all electrical equipment must comply with the provisions of the national electric code.
680 22 electrical equipment other than receptacles and lighting must be a minimum of five feet away fromthe swimming pool unless separated by a barrier.
If electric is required to supply a pool filter pump motor or a pool low voltage underwater light fixture listed and labeled for us with a storable pool that is 42 deep or less nec article 680 4 then your pool equipment must be served by a gfci protected.
2008 national electrical code 2010 residental code of new york state permanently installed swimming pools.
Top 10 major code changes to look out for in the nec 2017.
Electrical safety is very important especially around pools to ensure the safety of families and other guests.
1 pool pump receptacle outlet and wiring methods a.
Every electrical aspect of your pool needs to follow the code set forth by your local government.
680 23 wet niche luminaires that are installed in the foot well of a spa are only required to reach the bench area when removed for maintenance.
Many code users were unclear if the exception was a carte blanche exception to 680 43 d or just to 680 43 d 4.
All electrical equipment used with storable pools are required to be gfci protected.
The only electrical requirements to a storable above ground pool are as follows.
Passed in 1968 the swimming pool code applies to new construction and reconstruction for all equipment in the image above.
680 9 overhead wire clearance is min.
Thanks for your electrical question sue.
2017 national electrical code sps 316 swimming pool wiring nec article 680 680 5 gfci s may be either circuit breakers or receptacle type.
For added protection of all new pool installations the 2017 nec national electrical code article 680 has been amended.
If the pool is an above ground and is considered storable then the following codes apply.
All 125 volt outlets or receptacles within 2o feet of the inside walls of a pool require gfci protection.
National electrical code definition are those pools that are constructed or partially in the ground all others pools capable of holding water with a depth greater than 42 inches.
Before you can jump into your pool or spa there are legal loops you have to jump through first.
While changes to the code are gradual it is always a good idea to check on the requirements of the latest edition of the nec.
Article 680 and not just pool lighting.
No matter what size or type of pool or spa you invest in it will most likely depend on electrical equipment for filtering and heating water operating the cover lights pumps and other functions.
Hydromassage bathtubs when a hydromassage tub is cord and plug connected it s common to find the receptacle beneath the tub arranged such that it s nearly impossible to see much less use.